Apr 20, 2018

Magnetic Separator Fault Analysis

Leave a message

Magnetic Separator Fault Analysis


(1) The magnetic separator motor overheats and its sound is abnormal.

 

The reasons for the motor overheating and abnormal sound of the magnetic separator are: 1) The bearing has poor lubrication or serious wear; 2) The fan blade is detached or worn out; 3) The switch circuit is connected. Bad touch, or single-phase break running; 4) The voltage is too low.

 

(2) The sound of the magnetic separator is abnormal during operation, the cylinder is jammed by obstacles, and even the cylinder cannot rotate, and the bottom box vibrates.

The reason is that the object is often stuck in the bottom case, and then the magnetic block falls off, causing the cylinder to buzz, and in severe cases the skin can be scratched. At this time, you should stop and troubleshoot.


(3) Overheating of reducer

The reasons are: 1) Insufficient oil or poor oil quality; 2) Worn gears and worm gears, or poor meshing; 3) Abnormally lubricated or heavily worn bearings.

 

(4) Magnetic separator weakens magnetic field strength

The reasons are: 1) high temperature; 2) sun exposure; 3) acid and alkali corrosion. Can be measured with a Gauss meter. The magnetic separator consists of a base, a lower magnetic system, a rotating cage, an upper magnetic system, a hollow shaft, a concentrate tank, and a transmission. The mounting base measures the elevation and leveling of the hollow shaft holder. The positioning of the lower magnetic system is based on the base. The clearance adjustment between the cage and the upper and lower magnetic systems must be accurate, and the clearance limit deviation is 0+1mm.