Overview
The RCDB series disk electromagnetic iron remover produced by our factory is used together with a belt conveyor, mainly to remove ferromagnetic substances mixed in non-magnetic bulk materials. It is mainly used for the iron press of any material on the roller press, vertical mill, and various secondary crushers of the cement plant before entering the mill and on the belt conveyor. The equipped KGLA20A/250V power box is used to control the DC current of the iron remover from small to large current, thus changing the iron absorption capacity of the iron remover.
Since the coil of the iron remover shell is installed in a totally enclosed manner, collisions of the inner thread packs due to various reasons are avoided. In view of the above advantages, the iron remover produced by our factory is well received by the users.
Electromagnetic iron remover is an indispensable protective device for crushers and an effective assistant to improve product quality.
I plant this series of products in line with JB/T7689-2004 national standards. Has the characteristics of attraction, light weight, reasonable price and continuous work.
Second, the main structure and working principle
The main structure consists of an excitation system, a junction box and a sealed enclosure.
Excitation system: It is composed of a high magnetic core and excitation coil.
Junction box: It is composed of wiring device and sealing device.
The shell is made of iron plate with special magnetic material.
Working principle: When the external power supply passes through the power control box, the alternating current is converted into a direct current. When the excitation coil is passed through, the magnetizing force is generated due to the flow of the current, and a strong magnetic field is formed on the pole surface, which is conveyed by the conveyor belt. When the material passes under the electromagnetic separator, the ferromagnetic material mixed in the material can be continuously adsorbed under the strong magnetic force so as to achieve the purpose of removing iron.
The DC power control box of this series of electromagnetic iron remover can be configured with the KGLA silicon controlled rectifier power supply produced by our factory.
Third, the model significance and basic norms
1. Expression of the type meaning:
2. Main technical and specification parameters:
3. Wiring diagram:
Fourth, installation and adjustment
1. First remove the dust that has accumulated on the way.
2. Check that the insulation resistance of the separator is not less than 1 megohm. Such as due to dampness should be used after drying. (The drying method uses the factory's supporting power supply.) Pass the separator coil to the DC voltage of 1/3 of the rated voltage. After 2-3 hours, cut off the power and measure it with a 500 megohm meter. The insulation resistance should not be lower than If the specified value is lower than the specified value, it should continue to be energized until it reaches the specified value before it can be put into use.
3. During the installation, please refer to the installation diagram for installation. It can also be designed and installed according to the needs of the factory and the location of the model.
4. Electrical schematic:
V. Use and maintenance
1. The DC power supply has a rubber sleeve and the cable is connected to the terminal bolts in the terminal box.
2. Always check the voltmeter and ammeter readings to control the normal operation of the separator.
3. When the adsorbent on the electromagnet reaches a certain degree, it should be de-energized and demagnetized. After removing the attached matter, it can continue to operate.
Six, matters needing attention
1. This machine should be reliably grounded;
2. The cable connecting the thyristor and the iron remover should be installed in the pipe or shield that can prevent mechanical damage;
3. Do not approach the iron remover with the iron catcher during operation. Also, remove iron from the conveyor belt by hand to prevent personal injury.
4. The line voltage should not exceed ±3% of the rated value. If it is lower than the allowable value, it will reduce the effective attraction; if it is higher than the allowable value, it will cause the coil to heat, accelerate the aging of the raw materials, and shorten the service life.